SPARKX i7, i8
This message indicates that a possible hardware fault has been detected in the bed leveling sensor, which may affect Z-axis homing and bed leveling.
Check the wiring: Make sure the bed leveling sensor cable is securely connected and check for loose or disconnected connections.
Replace the sensor: If the issue persists after inspection and cleaning, the bed leveling sensor may need to be replaced to restore normal operation.
- Check the bed leveling sensor wiring and make sure the connection is secure.
- Inspect the sensor and make sure no foreign objects are interfering with its operation.
- If the issue persists, consider replacing the bed leveling sensor. Refer to the replacement guide: i7 Bed Leveling Sensor Replacement Guide, i8 Bed Leveling Sensor Replacement Guide.
- Restart the printer, select Z-axis homing, and check whether normal operation has been restored.