This error is triggered when an open circuit is detected in the nozzle thermistor.
Possible causes include:
- There may be an issue with the hotend thermistor wiring. Check the wiring and make sure it is properly connected.
- The hotend thermistor may be damaged, and the hotend heating assembly may need to be replaced.
Thermistor wiring issue: Check the thermistor wiring and make sure the connection is not loose or damaged. If there is a wiring issue, reconnect it securely and confirm that the connection is stable.
Damaged thermistor: If the thermistor wiring is properly connected but the temperature reading on the screen is negative, replace the hotend heating assembly.
- Check the thermistor wiring and make sure the connection is not loose or damaged.
- If the thermistor wiring is properly connected but the temperature reading on the screen is negative, replace the hotend heating assembly.
- For detailed replacement procedures, refer to: i7 Hotend Heating Assembly Replacement Guide, i8 Hotend Heating Assembly Replacement Guide.