SPARKX i7, i8
This error is triggered when the part cooling fan speed is lower than expected. Possible causes include:
- The fan connector is loose or has poor contact, preventing the fan from operating properly.
- The fan is obstructed or jammed, preventing it from spinning normally.
- The fan speed feedback signal is faulty, preventing the printer from detecting the actual fan speed.
- Connection Issue: Check that the fan connector is securely connected and has no poor contact. If necessary, disconnect and reconnect it securely.
- Fan Is Jammed: Check whether foreign objects are blocking the fan or preventing it from spinning freely. Remove any obstructions and make sure the fan can rotate smoothly.
- Faulty Fan Speed Feedback Signal: If the fan is properly connected and spins normally but the error persists, the fan speed feedback signal may be faulty. Replace the part cooling fan.
- Check the part cooling fan connector and make sure it is securely connected.
- Set the part cooling fan speed to 100%. Observe the fan and confirm that it can spin freely.
- If the fan or its speed feedback signal is faulty, replace the part cooling fan. Restart the printer and check whether the issue is resolved. For replacement instructions, refer to the i7 Model Cooling Fan Replacement Guide, i8 Model Cooling Fan Replacement Guide.