¶ 950761: Unable to Read the Extruder Leveling Sensor Data. The Cable Between the Extruder and Mainboard May Be Loose or Disconnected
SPARKX i7, i8
Possible causes include:
- The toolhead ribbon cable is loose, improperly connected, or damaged.
- The communication bus cable between the mainboard and adapter board is loose, improperly connected, or damaged.
Cable Connection Issue:
Check the toolhead ribbon cable and communication bus cable. Make sure they are securely connected and undamaged. If a connection is loose, reconnect the cable securely.
Damaged Cable:
If all connections are secure but the printer still does not work properly, replace the toolhead ribbon cable or communication bus cable.
- Check the toolhead ribbon cable and make sure it is securely connected and undamaged.
- If the cable is loose or improperly connected, reconnect it securely and check that the connection is stable.
- If the connection is secure but the printer still does not work properly, replace the affected cable.
- Home the Z-axis and check whether the issue is resolved.