The angle data is abnormal and it has stopped working.
Please check whether the workbench is shaking, the screws are locked tightly and the frame of the machine is firm.
There is no G-Code file in the root directory of the TF card.
Please check whether the suffix of the file in the TF card is ".gcode/.gc/.nc ", and ensure the file is saved in the root directory.
No airflow is detected and the machine has stopped working.
Please check whether the air pump is connected to the machine, check whether the knob switch on the left side of the machine is adjusted to the maximum, and check whether the silicone air tube above the laser module is inserted and there is no kinks in the tube.
In the Falcon Machine Settings you can change: $153 to 0 to cancel the alarm function (it is recommended to set it according to the actual situation).
A flame has been detected and the machine has stopped working.
Please press the Reset button if the material is not burning, and the FIRE light will turn orange, indicating that there is a risk of fire. You can press the start button to continue working and after restarting the machine, the FIRE light will be green. Refer to “Laser Module Alarm Functions.pdf” for more information.
In the Falcon Machine Settings you can change: $154 to 0 to cancel the alarm function (it is recommended to set it according to the actual situation).
Lens contamination is detected and the machine has stopped working.
Please press the Reset button and the LENS light will turn orange. You can press the start button to continue working and the lens needs to be cleaned when powered off. The LENS will still keep red light flashing when power on. You need to press the reset button again to confirm that the lens is clean and the LENS light will be green. Refer to “Laser Module Alarm Functions.pdf” for more information.
In the Falcon Machine Settings you can change: $155 to 0 to cancel the alarm function (it is recommended to set it according to the actual situation).
The temperature of the laser module is high and it has stopped working.
You can press the Reset button and then press the Start button to continue the current work.
It is recommended to clean the laser module when powered off and wait for the laser module to cool down to a suitable temperature before working.
In the Falcon Machine Settings you can change: $158 to 0 to cancel the alarm function (it is recommended to enable the alarm function).
The air pressure sensor of the laser module is not performing correctly.
It is recommended to restart the machine to see if it is solved. If the error persists, please contact the after-sales service for relevant technical support.
The flame sensor of the laser module is not performing correctly.
It is recommended to restart the machine to see if it is solved. If the error persists, please contact the after-sales service for relevant technical support.
The lens sensor of the laser module is not performing correctly.
It is recommended to restart the machine to see if it is solved. If the error persists, please contact the after-sales service for relevant technical support.
The laser module does not have an LD temperature sensor.
It is recommended to restart the machine to see if it is solved. If the error persists, please contact the after-sales service for relevant technical support.
Laser module LD sensor short circuit.
It is recommended to restart the machine to see if it is solved. If the error persists, please contact the after-sales service for relevant technical support.
The CPU temperature of the laser module is too high.
It is recommended to clean the laser module after power off and wait for the laser module to cool to the appropriate temperature before working.
The temperature of host CPU is too high.
Please check whether the ambient temperature is too high. It is recommended to wait for the host to cool down to a suitable temperature before working.
The machine is in an unsealed state.
Please close the protective cover and drawer, and then press the start button of the device to continue working.
The air pump is not performing normally.
Please contact the after-sales service for relevant technical support.