Error code | Description | Processing Method |
01001001 | G-code words consist of a letter and a value. Letter was not found. | Gcode file error, check Gcode content |
01001002 | Missing the expected G-code word value or numeric value format is not valid. | Gcode file error, check Gcode content |
01001004 | Negative value received for an expected positive value. | Illegal command, check command content |
01001005 | Homing cycle failure. Homing is not configured via settings. | Homing command error, check homing command configuration or restore factory settings |
01001008 | '$' command cannot be used unless controller state is IDLE. Ensures smooth operation during a job. | Wait for the device to be idle before operating |
01001009 | G-code commands are locked out during alarm or jog state. | Wait for the device to be idle before operating |
01001010 | Soft limits cannot be enabled without homing also enabled. | It is recommended to restore factory settings |
01001013 | Safety door detected as opened and door state initiated. | Safety door triggered, please close the protective cover before operation |
01001015 | Jog target exceeds machine travel. Jog command has been ignored. | Check the position or travel of the Jog command |
01001016 | Jog command has no '=' or contains prohibited g-code. | Check if the Jog command format is correct |
01001019 | Non positive value | Check if the Gcode or '$' command parameters are correct |
01001020 | Unsupported or invalid g-code command found in block. | Check if the Gcode is correct |
01001021 | More than one g-code command from same modal group found in block. | Check if the Gcode is correct |
01001022 | Feed rate has not yet been set or is undefined. | Check if the Gcode is correct, F (feed rate) parameter is missing |
01001023 | G-code command in block requires an integer value. | Check if the Gcode is correct |
01001024 | More than one g-code command that requires axis words found in block. | Check if the Gcode is correct, possibly attempting to operate an axis other than XYZA (unsupported) |
01001025 | Repeated g-code word found in block. | Rarely occurs, can be ignored; if it appears, check if the Gcode is correct |
01001026 | No axis words found in block for g-code command or current modal state which requires them. | Check if the Gcode is correct, possibly missing movement axis command |
01001027 | Line number value is invalid. | Check if the Gcode is correct |
01001028 | G-code command is missing a required value word. | Check if the Gcode is correct |
01001036 | Unused value words found in block. | Rarely occurs, can be ignored; if appears, check if Gcode is correct |
01001039 | Value out of range. | Check if the Gcode is correct |
01001045 | Only homing is allowed when a limit switch is engaged. | Rarely occurs, can be ignored; if appears, check limit switch wiring |
01001046 | Home machine to continue. | Re-home the machine |
01001051 | Motor fault. | Motor driver initialization failed (usually occurs at power-on) |
01001053 | Setting is not available, possibly due to limited driver support. | Only occurs when $ parameters are illegally modified in LightBurn/LaserGRBL - can be ignored |
01001302 | Target file path does not exist or lacks read/write permissions. | Print file path is invalid or not readable/writable |
01001303 | Target file type is unsupported; this may be due to an incorrect file extension. | Unsupported print file format |
01001304 | Error parsing the target file content, e.g., the file does not conform to the expected G-code format. | File parsing error |
01001305 | Target file read error: unable to read data from the file or device. | File read failure |
01001315 | SafeDoor Open | Safety door triggered - close protective cover before operation |
01001601 | Hard limit has been triggered. Machine position is likely lost due to sudden halt. Re-homing is highly recommended. | Hard limit triggered - needs homing to clear hardware limit |
01001602 | Soft limit alarm. G-code motion target exceeds machine travel. Machine position retained. Alarm may be safely unlocked. | Soft limit triggered - recommend homing once |
01001603 | Reset while in motion. Machine position is likely lost due to sudden halt. Re-homing is highly recommended. | Soft reset of Grbl during movement |
01001606 | Homing fail. The active homing cycle was reset. | Homing failed - retry homing |
01001607 | Homing fail. Safety door was opened during homing cycle. | Homing failed due to open safety door - close cover and retry |
01001608 | Homing fail. Pull off travel failed to clear limit switch. Try increasing pull-off setting or check wiring. | Homing failed - retry homing |
01001609 | Homing fail. Could not find limit switch within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring. | Homing failed - retry homing |
01001611 | Homing required. Execute homing command ($H) to continue. | Machine requires homing - manually home XYZ axes |
01001612 | Limit switch engaged. Clear before continuing. | The machine has triggered the limit switch, manual clearance or homing is required |
01001615 | Homing fail. Could not find second limit switch for auto squared axis within search distances. Try increasing max travel, decreasing pull-off distance, or check wiring. | Homing failed (rare occurrence), retry homing if this happens |
01001617 | Motor fault. | Motor driver abnormal - restart power supply |
01001618 | Homing fail. Bad configuration. | Homing failed - check configuration or restore factory settings |
01002001 | SafeDoor Open | Do not open cover during frame tracing, auto-focusing, operation, or pause recovery - close cover to continue |
02002001 | Laser Module upgrade failed | Check if Z-axis rear wiring is loose |
02002002 | File decompression failed | Delete USB files, re-download upgrade package, and re-upgrade |
04012002 | Flame detected, please ensure the fire is extinguished. | Flame alarm triggered - if machine doesn't avoid flames, manually power off and extinguish |
04011003 | Abnormal air pressure, please check the air pump pipe for leaks. | Check air pump tubing for leaks |
04011004 | Laser module overheating, please stop using until the temperature drops. | Wait until machine returns to normal temperature (5-30°C) before restarting |
04011020 | Laser module overheating, please stop using until the temperature drops. | Wait until machine returns to normal temperature (5-30°C) before restarting |
04012006 | Laser module flame sensor abnormal | UI alert: "Check laser module wiring. If error persists after confirmation, contact support" |
04012008 | Laser module lacks NTC sensor | UI alert: "Check laser module wiring. If error persists after confirmation, contact support" |
04012009 | Laser module NTC sensor short circuit | UI alert: "Check laser module wiring. If error persists after confirmation, contact support" |
04012202 | Laser module heartbeat timeout alarm | UI alert: "Check laser module wiring. If error persists after confirmation, contact support" |
04031001 | Device tilted. Processing stopped. Please place it on a level surface to restart. | Print paused - beeper cyclic alarm |
04112001 | Air Pump Pressure Low Alarm | UI alert: "Check if air pump is on and wiring is correct. If error persists, contact support" |
04112099 | Acquire Air Pump Pressure Abnormal Alarm | UI alert: "Air pressure sensor abnormal - contact support" |
04132001 | Low temperature alarm ≤ -10 ° | Operate machine only in 5-30°C environments |
04132002 | High temperature alarm ≥ 50 ℃ | Operate machine only in 5-30°C environments |
07001001 | Flame detected, please ensure the fire is extinguished. | Power off machine and clear fire situation |