The nozzle pick-and-place coordinate calibration is used to reconfirm the position of the nozzle parking mechanism, correct the coordinates used when the machine picks up and returns nozzles, and make nozzle switching more accurate.
After transportation, relocation, or disassembly/maintenance, the position of the parking mechanism may have shifted slightly, resulting in:
Nozzle pick-up failure;
Nozzle return failure;
Inaccurate pick-and-place position;
Nozzle switching failure during printing.
After calibration is complete, the machine will correct the pick-and-place coordinates based on the detection results and perform a pick-and-place verification.
This feature is intended to resolve pick-and-place position deviation and cannot fix loose components, improper installation, foreign object obstruction, or mechanical damage.
Calibration is recommended in the following situations:
After initial installation or after the device has been transported or relocated;
After a firmware update, when the system prompts that recalibration is required;
After the nozzle or nozzle parking mechanism has been disassembled, reassembled, or serviced;
When nozzle pick-up, return, or switching exceptions occur, and foreign objects, loose parts, and installation issues have already been ruled out;
When the system prompts that the nozzle pick-and-place coordinates are abnormal.
If nozzle pick-and-place is functioning normally, frequent calibration is not necessary.
During calibration, the printer sequentially detects the mechanical reference positions in the X and Y directions.
The system determines the positional offset of the nozzle parking mechanism based on the detection results and recalculates the pick-and-place coordinates for each nozzle.
In simple terms, the printer reconfirms:
"Where is the nozzle parking rack now, and where should each nozzle be picked up and placed?"
What Preparations Are Needed Before Calibration?
Please confirm the following before starting:
The printer is in an idle state;
No printing, filament loading, unloading, or nozzle switching is in progress;
There are no foreign objects inside the printer;
The nozzle and parking mechanism are properly installed.
During calibration, do not move the printer, push the printhead, or manually operate any internal mechanisms.
How to Perform Nozzle Pick-and-Place Coordinate Calibration?
Navigate on the printer to:
Settings → Calibration → Nozzle Pick/Place Coordinate Calibration
After selecting Start Calibration, the printer will automatically execute the entire process.
Homing Preparation
The printer first performs the necessary axis homing operations to establish the machine's base coordinates.
Y1 Axis Calibration
The printer detects the first mechanical reference position in the Y direction.
Y2 Axis Calibration
The printer detects the second mechanical reference position in the Y direction.
X Axis Calibration
The printer detects the mechanical reference position in the X direction.
Calculate and Save Nozzle Coordinates
The system recalculates the pick-and-place position of each nozzle based on the detection results.
Pick-and-Place Result Verification
After calibration is complete, the printer performs a nozzle pick-and-place test to confirm that the new coordinates function correctly.
The entire process can typically be completed within a few minutes.
During calibration, you can view the current progress directly by following the step-by-step prompts on the screen. Completed steps will be displayed as finished; if an exception occurs at any step, the printer will stop calibration and display a corresponding prompt.
Important Notes Regarding Nozzle #1
This feature requires Nozzle #1 to complete the calibration and verification.
When calibration begins, the printer will automatically attempt to pick up Nozzle #1 (T0).
If automatic pick-up of Nozzle #1 fails:
Wait for the printer to stop moving;
Check the position of Nozzle #1;
Manually mount Nozzle #1 following the on-screen prompts;
After confirming it is properly installed, continue or retry as prompted by the current screen.
Do not manually operate the nozzle while the printer is in motion.
If calibration still cannot be completed after manual mounting, check whether the nozzle or parking mechanism has any foreign objects, loose parts, or mechanical interference.
Do not move the printer or push the printhead, as this may affect the calibration results;
Keep the nozzle parking area clean to prevent filament debris or foreign objects from interfering with detection;
Do not power off the printer during calibration;
When nozzle pick-and-place is functioning normally, frequent recalibration is not necessary.
Slight mechanical contact sounds such as "click" or "clack" during calibration are normal.
How to Determine Whether Calibration Was Successful?
After calibration is complete, the printer will automatically perform nozzle pick-and-place verification.
Once verification is successful, the new coordinates will take effect automatically with no additional settings required.
If verification fails, check the device status following the on-screen prompts and perform the calibration again.
Why does the printhead contact reference positions inside the machine body during calibration?
This is normal.
The printer makes very small movements to contact the mechanical reference positions in order to determine the actual coordinates and calculate the positional offset of the nozzle parking mechanism. Please do not manually interfere with printhead movement during calibration.
Why is Nozzle #1 specifically required?
Nozzle #1 is one of the reference nozzles in this calibration process. The system needs it to complete the relevant nozzle pick-and-place operations and final verification.
Therefore, if the machine cannot pick up Nozzle #1 normally, calibration cannot continue, and Nozzle #1 must first be manually mounted following the on-screen prompts.
Is calibration required before every print?
No.
Under normal circumstances, the nozzle pick-and-place coordinates are saved in the printer. Recalibration is only recommended when the device has been serviced, its position has changed, or nozzle pick-and-place exceptions occur.
Will calibration affect print parameters?
No.
Nozzle pick/place coordinate calibration is only used to correct the positions for nozzle pick-up and parking. It does not modify model, slicing, or material parameters.
Is it normal to hear a "beep, beep, beep" sound during calibration?
Yes, it is normal.
The pick-and-place coordinate calibration relies on slight contact between the extruder and the mechanical reference stoppers to collect data. This process generates a faint "beep, beep, beep" tapping sound, which is a normal occurrence.