¶ TE3209: The extruder open/close mechanism failed to open. Please confirm whether the open/close mechanism is functioning normally, try manually removing and replacing the nozzle, then retry.
When picking up or returning the nozzle, the active open/close mechanism failed to open.
Check the open/close mechanism itself
Confirm whether the extruder open/close mechanism can open and close normally
Check whether the buckle/locking mechanism has any wear or deformation
Clean filament debris from around the open/close mechanism
¶ Manual handling
Try manually returning the nozzle to the target station, then perform the nozzle pick-and-place action again.
Check whether the alignment between the nozzle and the station is offset.
Check whether the extruder open/close mechanism is functioning normally.
Check whether there are any collisions or obstructions in the X/Y axis movement.