¶ TE3206: Nozzle retrieval failed — nozzle was not picked up. Please verify that the nozzle is positioned correctly, then try manually placing and removing the nozzle before retrying.
The extruder moves in the Y direction to pick up the nozzle, but the coordinate position is not aligned, causing the nozzle to not be picked up by the extruder and resulting in a retrieval failure.
- Check Y-axis movement and alignment
Confirm whether the Y-axis movement is smooth, and check for any jamming or abnormal noise
- Check whether the nozzle rack station has any deformation or misalignment
Confirm whether the Y-direction coordinates of the extruder and nozzle are aligned; recalibrate if necessary
¶ Manual handling
Try manually mounting the nozzle onto the extruder, then perform the nozzle pick-and-place action again.
- Check whether the nozzle and station alignment is offset.
- Check whether the extruder opening and closing mechanism is functioning properly.
- Check whether there are any collisions or obstructions in the X/Y-axis movement.