¶ TE3205: Nozzle retrieval failed. No nozzle available at Station 2. Please verify the station status and try again.
Before the retrieval action is executed, the system needs to confirm that a nozzle is present at the target station. If no nozzle is detected at the target station, an error will be reported.
If there is indeed no nozzle at the station → Place the corresponding nozzle correctly into the station.
If a nozzle is present at the station but the error still occurs → Proceed to the next step.
Check whether the nozzle has fully dropped into the station slot, and whether it is tilted or raised.
Check whether there is any residual filament or foreign object inside the station that is preventing the nozzle from seating properly.
Check whether the presence sensor (Hall sensor) at the station is blocked, loose, or damaged.
Check whether the Hall sensor at the nozzle rack station is functioning properly.
Check whether the nozzle placement position is misaligned, causing the sensor to misjudge.