- Socket wrench
- Thermal grease
- New nozzle
- Heat up the nozzle to 200°C (392°F).
- Lower the platform to the middle or below to empty operation space.
- Remove the magnetic extruder cover.
- Use a straight socket wrench to unscrew the old nozzle.
If the straight wrench cannot loosen it, use an angled socket wrench first to loosen the nozzle, then use the straight wrench to unscrew it completely.
- Take the new nozzle and apply thermal grease evenly to the pipe.
- Use the straight socket wrench to screw on the new nozzle, ensuring it is tightened fully.
- Reinstall the magnetic extruder cover.