The error code summary is designed to facilitate the location of printer failures.
If you encounter an error code, you can follow the instructions on the screen or view this document to solve it. If you can find the error code in the table, follow the process to solve it.
If you cannot find the error code in the table, you can export the log and send it to after-sales customer service for analysis.
Code |
Screen Popup Content |
Explanation |
Solution |
100 |
/ |
Copy U disk gcode file to local; Copy error, do not start printing | / |
101 |
/ |
Printing process AI detects pasta phenomenon and suspends printing Possible reasons: 1. Use color filaments to trigger by mistake 2. Printing failure |
1. If you can continue to print under the wrong trigger condition or manual judgment, you can click on either the printer screen/slicing software or Creality Cloud to continue printing 2. If the printing fails, clean the printer and restart again 3. Turn off the function in the System Settings - Camera -AI function |
102 |
/ |
The current gcode file name is too long | / |
103 |
AI detection prompt Key:103,A print quality problem has been detected and printing has been paused |
The detection result of the first layer is abnormal, and the printing is suspended Possible reasons: 1. The first layer of the model is blown up 2. It is triggered incorrectly |
1. If you can continue to print under the wrong trigger condition or manual judgment, you can click on either the printer screen/slicing software or Creality Cloud to continue printing 2. If the printing fails, clean the printer and restart again 3. Turn off the function in the System Settings - Camera -AI function |
104 |
Error Key:104,Foreign object detected on the printing platform, printing paused |
Abnormal detection of foreign matter in hot bed, suspend printing Possible reasons: 1. The surface of the printing platform has a special pattern triggered by mistake 2. The surface of the printing platform has residual glue white triggering by mistake 3. The printing platform is triggered by placing other items |
/ |
108 | / | Lidar offset correction failure | / |
109 |
Error Key:109,Fan feedback exception |
The pipe fan is abnormal. Stop printing | / |
110 | / | The primary MCU hardware connection is abnormal | / |
111 | / | The hardware connection of the hotend MCU is abnormal | / |
112 | / | The hot bed MCU hardware connection is abnormal | / |
500 |
AI detection prompt Key:500,Printing quality problems detected by AI |
Print process AI detects pasta phenomenon and only prompt.The hot bed MCU hardware connection is abnormal | / |
501 |
Error Key:501,Heat break fan exception |
The pipe fan is abnormal Possible reasons: 1. The cable terminal is loose; 2. During the installation, the fan is deadlock and cannot turn; 3. The fan is damaged |
1. Remove the hotend cover and nozzle plate, check whether the screws fixing the heat dissipation block fall into the pipe fan, and tighten the screws fixing the heat dissipation block fan. 2. Reinsert the terminal of the pipe fan 3. Replace the pipe fan |
502 |
Error Key:502,Mainboard fan exception |
The mainboard fan is abnormal. Possible reasons: 1. The cable terminal is loose 2. During the installation, the fan is deadlock and cannot turn 3. The fan is damaged |
/ |
503 | / | If the first-layer detection is abnormal, only prompt. | / |
504 |
AI detection prompt Key:504,Current file does not support flow detection |
If the internet traffic detection is abnormal, only prompt. | / |
505 |
AI detection prompt Key:505,AI LiDAR anomaly |
Lidar doesn't exist, only prompt. |
1. Check cable connections to the lidar 2. Replace the Lidar |
506 |
AI detection prompt Key:506,AI LiDAR calibration failure |
Lidar calibration failure, only prompt | / |
507 |
AI detection prompt Key:507,AI LiDAR alignment failure |
Lidar calibration failure, only prompt. | / |
508 |
Error Key:508,Current storage space usage has reached %s, please clean up in time |
/ | / |
2000 |
Error Key:2000,Unknown exception |
Unable to update the MCU configuration because the MCU is closed | Re-startup first; Check connection |
2001 |
Error Key:2001,Unknown exception |
1. The register status of the E-axis driver IC cannot be read, and a timeout occurred 2. The communication wire between the mainboard and the hotend is in poor contact or interfered with, resulting in time-out of the hotend MCU communication |
1. Reissue the hotend plate. 2. Reissue the hotend cable. |
2002 | / | The mainboard fails to connect | / |
2014 | / |
The slicing distance is negative or greater than the entire moving length Possible reasons: 1. The problem of printing file, either without using official slicing software, or choosing the wrong model 2. System error |
1. Check whether the official slicing software is used; whether the third-party slicing software configuration is officially provided; whether the official slicing software is selected for the right model 2. Restart the printer and then print again |
2016 | / | Printing is not paused, resume suspense | / |
2019 | / | The target temperature {0} is out of the setting range ({1}:{2}) | / |
2020 | / | Homing error: {0} | / |
2021 | / | {0}Homing timeout error | / |
2056 | / | {0}-axis accelerometer unable to measure data | / |
2057 | / | Unknown Exception | / |
2060 | / | / |
1. Unplug the hotend terminal 2. Replace the hotend connection cable 3. Re-startup |
2065 | / | Fail to set ADXL345 register [0x%x] to 0x%x: Got 0x%x. This typically indicates a connection problem (such as a wiring fault) or a faulty ADXL345 chip. | Replace the hotend board |
2069 | / | There is "M107 P3" code in the slicing file | Check whether the slicing software is the latest version and re-slice |
2090 | / | The timer goes off, which usually indicates that the mainboard is overloaded. | / |
2091 | / | Miss the next plan. This usually indicates an intermittent communication failure between the microcontroller and the mainboard. | / |
2095 | / | Must return to the origin first | / |
2111 |
Error Key:2111,Unknown exception |
The extrusion temperature is lower than the minimum temperature set by the printer configuration. The minimum extrusion temperature of CrealityOS is 170 degrees. |
1. For slicing problems, please use the official slicing software or contact the official website to use the third-party slicing software configuration file provided by the official website. 2. For key2507 problems, stop printing and heat the nozzle. If the error ket2507 is reported, refer to the 2507 error troubleshooting. |
2112 | / | Movement exceeds maximum extrusion ({0}mm^2 vs {1}mm^2) <br /> Please refer to Maximum Extrusion Cross Section configuration option for related information | / |
2113 | / | Extrude fails to configure | / |
2114 | / | Extrusion without extruder | / |
2115 | / | Unknown value {0} in enumeration type {1} | / |
2116 | / | Invalid output format {0} | / |
2117 | / | Extra data at the end of the message | / |
2118 | / | Unable to query adxl345 fifo | / |
2119 | / | Invalid adxl345 id (got {0} vs {1}). This usually indicates a connection problem (e.g. a wiring fault) or a faulty adxl345 chip | / |
2210 | / | Unable to automatically load filament, extruder is below minimum temperature | / |
2211 | Pause Printing | ||
2242 | Reset to homing first: {0} {1} {2} [{3}] | ||
2243 | Out of range: {0} {1} {2} [{3}] | ||
2252 | The minimum value of parameter {0} must be {1} | ||
2253 | The maximum value of parameter {0} must be {1} | ||
2283 | Printer Not Ready | ||
2294 | Response Timeout | Export log and contact us cs@creality.com | |
2295 | An attempt to restart MCU {0} fails | ||
2298 | Unable to update MCU {0} configuration because it has powered off | ||
2299 | Unable to configure MCU {0} | ||
2300 | MCU {0} error during configuration: {1} | ||
2308 | {0}-axis accelerometer fails to measure data | ||
2313 | Internal error while processing accelerometer data {0} | ||
2340 | Heater %s requested temperature (%.1f) is out of range (%.1f:%.1f) | ||
2343 | Main MCU connection timeout | ||
2344 | Hotend MCU connection timeout | ||
2345 | Hotbed MCU connection timeout | ||
2503 |
Error Key:2503,Unknown exception |
Unable to read Z-axis strain gauge data | |
2504 |
Error Key:2504,Unknown exception |
Z-axis homing exception | |
2505 |
Error Key:2505,Unknown exception |
Motor driver chip TMC exception Possible reasons: Overheating: Mainboard fan exception, low voltage: Printing speed too fast |
|
2506 |
Error Key:2506,Unknown exception |
Communication exception Possible reasons: Common problems: 1. hotend wire problem |
|
2509 |
Error Key:2509,Unknown exception |
Nozzle Sensor temperature exception | |
2510 |
Error Key:2510,Unknown exception |
Hotbed Sensor temperature exception | |
2511 |
Error Key:2511,Unknown exception |
Cavity temperature exception | |
2512 | The main MCU chip temperature is abnormal | ||
2513 | The command format is incorrect | ||
2514 | The command parameter format is incorrect | ||
3002 |
When no printing, the nozzle communication is abnormal, and the hotend wire on the mainboard is not plugged in properly Possible reasons: Check the terminal contact problem on the mainboard |
||
2520 |
The reading of the pressure sensor timeout, that is, it takes 11ms to read HX711, but the actual HX711 is still not ready after more than 25ms. Possible reasons: Z-axis sensor chip is abnormal |
Please contact cs@creality.com, if it happens frequently. | |
2521 |
Error Key:2521,Leveling Sensor Chip Anomaly or Sensor Damage |
The pressure data reading is a fixed value, such as -1 Possible reasons: Z-axis sensor chip is abnormal or the sensor is damaged |
|
2522 |
Error Key:2522,Level Sensor Data Transmission Anomaly |
The pressure sensor cannot detect, that is, the collected pressure data does not change before and after placing a heavy object on the hot bed Possible reasons: Z-axis sensor chip is abnormal or the sensor is damaged |
|
2523 |
Error Key:2523,Level Sensor Data Transmission Anomaly |
During measurement, the serial port packet is lost, or the Z-axis is stuck and time out, resulting in loss of pressure data. Possible reasons: Z-axis sensor data transmission is abnormal |
|
2524 |
Error Key:2524, Leveling sensor chip abnormality, sensor damage or environmental impact. |
When the machine is stationary, the noise of the collected pressure data is too large Possible reasons: Z-axis sensor chip is abnormal, the sensor is damaged or affected by the environment |
|
2526 |
Error Key:2526,Z-axis movement not smooth or lead screw rotation not smooth |
The Z-axis motor lost steps during the leveling process, and after slowing down and retesting, it still lost steps Possible reasons: The Z-axis does not move smoothly, or the screw does not rotate smoothly |
|
2527 |
Error Key:2527,Level Sensor Data Transmission Anomaly |
During measurement, after triggering, the serial port packet loss causes incomplete motor step data received Possible reasons: Z-axis sensor data transmission is abnormal |
|
2529 |
Error Key:2529,Leveling sensor chip abnormality, sensor damage or environmental impact. |
G28 When the Z axis homing, the number of measurements exceeds the limit (maximum 20 times) Possible reasons: Z axis sensor chip is abnormal, the sensor is damaged or affected by the environment |
|
2532 |
Error Key:2532,Abnormal wiring connection or poor contact |
The synchronization wire between the two MCUs is not working properly (disconnected state) Possible reasons: Abnormal wiring connection or poor contact |
|
2533 |
Error Key:2533,Parameter anomaly, please re-leve |
CHECK_BED_MESH AUTO_G29=0, that is, leveling is not allowed, but the hot bed does not match the leveling data Possible reasons: Parameter exception |
|
2560 |
Communication with the main MCU exception Possible reasons: Communication with the lower computer is lost, and the upper computer has not received data for more than 5 seconds |
Check the wiring connection and restart | |
2561 | Communication between the hotend with MCU is abnormal | Check the wiring connection and restart | |
2562 | Communication between the hot bed with MCU is abnormal | Check the wiring connection and restart | |
2563 | Communication between the rpi with MCU is abnormal | Check the wiring connection and restart | |
2564 |
Error Key:2564,The nozzle is not heating as expected |
The hotend does not heat up as expected Possible reasons: The hotend heating has turned on, but the temperature does not rise |
Check the ceramic heating block and thermal wiring, reinsert the terminals, if they are damaged, please contact cs@creality.com |
2565 |
Error Key:2565,The heat bed is not heating as expected |
The hot bed does not heat up as expected Possible reasons: The hot bed heating has turned on, but the temperature does not rise |
Re-insert the hot bed wiring connection and check if the soldering position of the hot bed power supply is desoldered. If it is, please contact cs@creality.com |