During installation, the Z-axis motor cable position is easy to overlook. It is common to power on the device after installing the structural components without connecting the Z-axis motor cable, resulting in an error.
The printhead heating bracket is installed at an angle, causing nozzle deformation and triggering the strain gauge error prematurely.
Ensure the nozzle is in the latched state and properly installed.
Loosen the heat insulation pad screws and correct the tilt of the printhead heating bracket using the vertical alignment guide of the nozzle.
Lightly pre-tighten the right-side screw before tightening the left-side screw (Note: do not tighten all screws at once, as this may cause deformation and tilting on one side).