L-wrench x1
New five-way component x1
Place the bottom side of the CFS on while ensuring that the power is disconnected. Note that you need to press the terminal of the pneumatic connector before pulling out, otherwise the pneumatic connector may be pulled out.
Remove the three screws from the hub assembly
Remove the PTFE tube from the limit slot first
Disconnect the 4 PTFE tubes connected to the CFS. Please note that the terminal of the pneumatic connector must be pressed before pulling out, otherwise it may be pulled out
Disconnect cables from the motor and bottom control panel to take out the hub assembly
A wide cable is connected to the motor and a small cable is connected to the adapter plate
Connect the 4 PTFE tubes connected by CFS. Please note that the terminal of the pneumatic connector must be pressed before pulling out, otherwise the air head may be pulled out.
Press into the limit line slot