Creality Inspect is a 3D inspection software. By comparing a reference model with a scan model, it completes model alignment, deviation inspection, dimensional measurement, geometric tolerance evaluation, template inspection, and inspection report output.
The software includes the following modules:
Typical Use Cases
If you are using the software for the first time, start with Quick Inspection — it arranges the most commonly used functions in inspection order, and one walkthrough completes a full inspection.
Register and log in with a Creality account on first use. After logging in, you can create a new inspection project, open an existing project (*.crealityInspect), or continue from a recent project list.
The common inspection workflow is as follows:
New Project → Import reference model and scan model → Complete model alignment → Run deviation inspection → Create the required geometric features → Perform dimensional measurement or geometric tolerance evaluation → View inspection results → Generate report → Save project
The Quick Inspection toolbar is divided into the following groups in inspection order:
| Group | Functions | Description |
|---|---|---|
| Import | Import Model | Imports a reference model or scan model |
| Model Alignment | Automatic Alignment, Other Alignments | Automatic Alignment is applied with a single click; other alignment methods are available in the Other Alignments drop-down list |
| Deviation Inspection | Overall Deviation, Cross-Section Deviation, Curve Deviation | Calculates the deviation distribution on the model surface, cross-section, or curve |
| Deviation Annotation | Deviation Annotation | Adds annotations to the color map of Overall, Cross-Section, or Curve Deviation |
| Create Features | Buttons for points, lines, planes, circles, etc. | Creates the geometric features required for inspection |
| Datum and Coordinates | Create Datum, Create Coordinate System | Establishes inspection datums and measurement coordinate systems |
| Basic Measurement | Angle Measurement, Measure Length, Measure Radial Distance | Measures key dimensions of different features |
| Report Output | Create Report Page, Generate Report | Consolidates inspection data and outputs an inspection report |
The functions in Quick Inspection are identical to the functions of the same name in the Comparison and Measurement modules.
Import CAD or mesh models as inspection references or scan objects.
Supported models:
| File Type | Supported Formats | Purpose |
|---|---|---|
| CAD model | .igs, .iges, .step, .stp, .brep | Automatically used as the reference model |
| Mesh model | .ply, .stl, .obj, .qobj, .off | Selected by the user as the reference model or scan model |
The reference model represents the design intent or inspection datum of the product; the scan model represents the actual inspected object obtained by scanning.
Operation steps:
When a CAD model is imported, the software automatically sets it as the reference model.
When a mesh model is imported, the software prompts you to select the purpose of the file:
When multiple mesh files are imported at the same time, confirm the purpose of each file separately.

Caption: Figure 4-1 Selecting the file purpose when importing a mesh model
Model alignment is a prerequisite for model inspection.
General requirements:
Alignment Overview
Alignment Operation Level Constraint Basis Typical Use Core Input
Automatic Alignment Automatic Coarse Global iterative fitting General parts without explicit datum requirements Reference model, scan model, alignment mode
Manual Alignment Manual Coarse Feature points When automatic alignment performs poorly 3 manually matched point pairs
RPS Alignment Manual Fine Non-solid features (projected) Coarse alignment completed, high accuracy required 3 projected feature pairs
3-2-1 Alignment Manual Fine Coordinate system from three planes, 6 points in total Parts with clear three-axis datum planes 6 points
Coordinate System Alignment Manual Fine Local coordinate systems of both models Coordinate systems already built by the same rule Local coordinate systems
Datum Alignment Manual Fine Corresponding constructed geometry Evaluation per drawing datums, degrees of freedom must be controlled 3 corresponding constructed geometry pairs
Local Alignment Manual Fine Local region fitting Globally correct, locally out of tolerance At least 1 feature region
5.1.1 Coarse Alignment
If the inspection accuracy requirement is not high, subsequent inspection can be performed directly after coarse alignment; if high accuracy is required, perform fine alignment after coarse alignment.
Coarse alignment establishes the initial alignment of the models. The software provides two methods, Automatic Alignment and Manual Alignment, and both can serve as the starting point for fine alignment.
5.1.1.1 Automatic Alignment
Automatic Alignment is the recommended coarse alignment method for the first inspection.
Steps:
Alignment mode: use Standard mode when the model surface has clear structure; use High Precision mode when the surface structure is indistinct or flat. For rotationally symmetric parts, High Precision mode or Manual Alignment is recommended.

Caption: Figure 5-1-1 Import the models and confirm the alignment accuracy

Caption: Figure 5-1-2 Wait for the alignment to complete

Caption: Figure 5-1-3 Automatic alignment completed
5.1.1.2 Manual Alignment
Manual Alignment is a coarse alignment method performed manually when automatic alignment performs poorly.
Steps:
Feature point requirements: the three feature points on the same model must not be collinear and should be spread as far apart as possible. Prefer corners, hole positions, bosses, and other clearly defined structures.

Caption: Figure 5-1-4 Import the models and confirm the alignment accuracy

Caption: Figure 5-1-5 Manually pick points on the reference model

Caption: Figure 5-1-6 Manually select points on the scan model

Caption: Figure 5-1-7 Manual alignment completed
5.1.2 Fine Alignment
Fine alignment applies constraints on top of coarse alignment to perform a second alignment; the result is used for formal comparison and evaluation. The software provides five methods, distinguished by their constraint basis.
5.1.2.1 RPS Alignment
RPS Alignment is used when specified holes, planes, and other geometric features have inspection accuracy requirements.
Steps:
Note: RPS Alignment uses features with projection relations to constrain the alignment pose. If the projection relations are not established as required, this alignment method cannot be executed.

Caption: Figure 5-1-8 Confirm that coarse alignment is complete

Caption: Figure 5-1-9 Confirm that the reference and scan models have at least three groups of geometric features with projection relations

Caption: Figure 5-1-10 Select the geometric features with projection relations in the 3D view

Caption: Figure 5-1-11 RPS alignment completed
5.1.2.2 3-2-1 Alignment
3-2-1 Alignment aligns the scan model to a specified coordinate system and is used when the inspection requires a specified coordinate system.
Steps:

Caption: Figure 5-1-12 Confirm the coordinate system of the reference model in the 3D model

Caption: Figure 5-1-13 Confirm that coarse alignment is complete

Caption: Figure 5-1-14 Select or construct points on the scan model and preview the coordinate system position

Caption: Figure 5-1-15 3-2-1 alignment completed
5.1.2.3 Coordinate System Alignment
Coordinate System Alignment is a fine alignment method that uses the local coordinate systems of the reference model and the scan model as alignment constraints.
Steps:

Caption: Figure 5-1-16 Confirm that coarse alignment is complete

Caption: Figure 5-1-17 Create a coordinate system in the specified region of the reference model

Caption: Figure 5-1-18 Create the corresponding coordinate system in the same region of the scan model

Caption: Figure 5-1-19 Select the two coordinate systems to complete coordinate system alignment
5.1.2.4 Datum Alignment
Datum Alignment is a fine alignment method that uses corresponding geometric features on the reference model and the scan model to constrain degrees of freedom.
Steps:
Calculation mode: select Geometry to generate a standard alignment, or GD&T to generate an alignment associated with geometric tolerances.

Caption: Figure 5-1-20 Confirm that coarse alignment is complete

Caption: Figure 5-1-21 Construct 3 identical feature pairs on both models

Caption: Figure 5-1-22 Select the existing three feature groups

Caption: Figure 5-1-23 Datum alignment completed
5.1.2.5 Local Alignment
Local Alignment is a fine alignment method that focuses on optimizing the alignment of a local region.
Steps:
Note: Local Alignment is calculated only within the selected region. It removes the influence of the overall positioning and evaluates the local deviation separately.

Caption: Figure 5-1-24 Confirm that coarse alignment is complete

Caption: Figure 5-1-25 Select the local mesh region to be aligned on the scan model

Caption: Figure 5-1-26 Fit of the selected region after local alignment
Compare the reference model with the scan model to obtain the deviation distribution on the model surface, cross-section, or curve, and determine whether the part is out of tolerance.
Common prerequisites for all inspections in this chapter: the reference model and scan model have been imported and model alignment has been completed. Alignment accuracy directly affects the deviation values; if the alignment deviation is large, the calculation result is not meaningful.
Reading the results:
5.2.1 Overall Deviation
Compares the surface difference between the reference model and the scan model and generates a color-coded deviation map
The software provides two deviation calculation methods:
Operation steps:
The deviation result depends on alignment accuracy. If the distribution is clearly abnormal, check the alignment result first.

Caption: Figure 5-2-1 Calculate overall deviation based on the alignment result

Caption: Figure 5-2-2 Select the Shortest Distance Method

Caption: Figure 5-2-3 Overall deviation result
5.2.2 Cross-Section Deviation
Compares the profile difference between two models on a specified cross-section
Before use, complete model alignment and create the plane feature used for the cross-section in advance.
Operation steps:

Caption: Figure 5-2-4 Select the cross-section plane feature

Caption: Figure 5-2-5 Cross-section deviation result
5.2.3 Curve Deviation
Compares the shape difference between the reference curve and the corresponding curve on the scan model
Before use, complete model alignment and construct the reference curve in advance.
Operation steps:
Tip: when constructing the reference curve, hold Shift and use the point picking mode in the 3D view to select points on the CAD model.

Caption: Figure 5-2-6 Construct the reference curve

Caption: Figure 5-2-7 Curve deviation result
5.2.4 Dimensional Deviation
Compares the size, position, or orientation difference of associated features and judges pass/fail
Dimensional Deviation evaluates a pair of associated features: a reference feature on the reference model and a scan feature on the scan model. The association can be established by Best-Fit Projection or Associated Projection; the difference is whether the scan feature is generated by the software or created by the user.
Method 1: Best-Fit Projection (CAD feature first, scan feature fitted by the software)
Only the reference model needs a feature; the corresponding feature on the scan model is fitted automatically by the software.
Typical use: the reference model is a CAD model, the scan data is complete, and manual modeling should be minimized.
Operation steps:
If the fitting result is unsatisfactory, adjust the parameters above and fit again before running Dimensional Deviation.

Caption: Figure 5-2-8 Method 1: create a line feature on the CAD model

Caption: Figure 5-2-9 The created line feature

Caption: Figure 5-2-10 Apply Best-Fit Projection to the line feature

Caption: Figure 5-2-11 The line after Best-Fit Projection

Caption: Figure 5-2-12 Run Dimensional Deviation

Caption: Figure 5-2-13 Dimensional deviation result
Method 2: Associated Projection (features created on both sides, then associated manually)
Create features on the reference model and on the scan model separately, then establish their correspondence manually through Associated Projection.
Typical use: the scan model already has usable fitted features, or the correspondence between the two features must be controlled precisely.
Operation steps:
The reference feature and the scan feature must be located at the same structural position of the part and must be of the same geometric type (line to line, circle to circle, plane to plane). Otherwise the association cannot be established or the result is invalid.
Differences Between the Two Association Methods
| Item | Best-Fit Projection | Associated Projection |
|---|---|---|
| Feature creation | Only on the reference model | On both the reference model and the scan model |
| Source of scan feature | Fitted automatically by the software from the reference feature | Created manually by the user |
| Workload | Low; one projection completes the task | Higher; two features must be created and associated |
| Control precision | Depends on the fitting range and scan data quality | Better controllability; correspondence can be confirmed item by item |
| Typical use | Regular structures, complete scan data, efficiency-oriented | Incomplete scan data, complex structures, precise control required |
After the association is established by either method, the operation steps, result fields, and judgment rules of Dimensional Deviation are identical.
5.2.5 Deviation Annotation
Selects positions on the deviation map and displays the deviation value, tolerance range, and pass/fail status
Before use, complete the calculation of Overall Deviation, Cross-Section Deviation, or Curve Deviation.
Operation steps:
Deviation annotations can display:
Tip: annotations can be dragged by holding Shift. After the deviation result is deleted or recalculated, the corresponding annotations may need to be regenerated.

Caption: Figure 5-2-14 Deviation annotation result
5.2.6 Customizing the Color Scale
Adjusts the deviation range, tolerance range, and color display according to inspection requirements
Operation steps:
The color scale configuration is saved with the current project and applied to the inspection report.

Caption: Figure 5-2-15 Modify color scale colors

Caption: Figure 5-2-16 Modify color scale values
Measurement targets can be selected in three ways:
Point features created quickly with Shift are also listed under Geometric Features in the project tree and can be reused in later inspections.
This section applies to Angle Measurement, Measure Length, and Measure Radial Distance in Basic Measurement.
Create geometric features for alignment, measurement, and inspection from the CAD model, the scan model, or existing features.
6.2.1 Supported Feature Types
| Category | Features |
|---|---|
| Basic features | Point, line, plane |
| Profile features | Circle, ellipse, rectangle, polygon, slot, surface |
| Revolved features | Cylinder, sphere, cone |
A feature belongs to the model on which it is created. Subsequent alignment, measurement, geometric tolerance, and dimensional deviation can only reference features on the corresponding model, so confirm the target model before creating features.
6.2.2 Creation Modes and Applicable Models
| Creation Mode | Applicable Model | Description |
|---|---|---|
| CAD | CAD model | Extracts the corresponding geometric element from the CAD model |
| Fit | Scan model | Fits a geometric feature from a scan mesh region |
| Other creation modes | CAD model, scan model | Constructs a new feature from existing features or geometric relations |
When selecting a creation mode, note the following:
The overall workflow is the same for all three modes: select the feature type → select the creation mode → select the object → set the parameters → create. The operation details of each mode are described below.
6.2.3 CAD Mode
Extracts geometric elements such as points, lines, or planes from the CAD model
Operation steps:
Tip: hold Shift to select multiple CAD faces consecutively in the 3D view and create multiple features at once. CAD mode cannot be used on the scan model.

Caption: Figure 6-2-1 Creating a plane feature in CAD mode: hovering automatically recognizes and highlights the target face
6.2.4 Fit Mode
Selects a target region on the scan mesh and fits the corresponding geometric feature
Fit mode is commonly used to create fitted points, lines, planes, circles, cylinders, cones, and spheres.
Before use, import the scan model and confirm that the scan mesh contains a target region that can be fitted.
Operation steps:
Notes on fitting:
Fitted features can be used for Manual Alignment, 3-2-1 Alignment, datum and coordinate system creation, basic measurement, geometric tolerance evaluation, dimensional deviation, and feature projection.

Caption: Figure 6-2-2 Select the fitting region on the scan mesh

Caption: Figure 6-2-3 The fitted feature
6.2.5 Other Creation Modes
Constructs new features on the CAD model or the scan model from existing features or geometric relations
This mode can use features on the CAD model or features on the scan model, but the dependent features must be created in advance.
Common construction methods:
| Construction Method | Description | Typical Use |
|---|---|---|
| Intersection of two features | Constructs an intersection line or point from two planes or lines | Extracting parting lines and edges |
| Midpoint / endpoint | Derives a feature point from an existing line or circle | Establishing alignment locating points |
| Offset | Generates an offset feature at a specified distance from a plane or line | Building inspection datum planes |
Operation steps:
If an object cannot be selected, check whether the dependent features have been created and whether the feature type and selection order meet the requirements of the current construction mode.

Caption: Figure 6-2-4 Create a line from two points

Caption: Figure 6-2-5 Create a plane from a point and a direction
6.2.6 Feature Management
Created features are listed under Geometric Features in the project tree and can be renamed, centered, hidden, or deleted. After selecting multiple features at the same level, right-click and select Group to build a group.

Caption: Figure 6-2-6 Project tree context menu: centered, hidden, and deleted

Caption: Figure 6-2-7 Build a group after selecting multiple items

Caption: Figure 6-2-8 Grouping result
6.3.1 Datum
A datum is the reference used in geometric tolerances to determine the orientation and position of a geometric feature. The selection and order of datums directly determine the evaluation result.
6.3.1.1 Datum Composition
A datum is composed of features such as points, lines, and planes. The features used to construct a datum must first be generated through Create Features. The composition and applicability of datums are listed below.
Type Composition Applicability
Single datum One feature, such as a plane, a line, a point, or a circle When the drawing specifies only one datum
Multiple datums 2–3 features, such as line-plane, plane-plane, or a combination of three planes When the drawing specifies multiple datums with a defined order
Compound datum Multiple features of the same type or related features selected in the same input box When the same datum is composed of multiple features on the drawing
6.3.1.2 Rules
6.3.1.3 Creating a Datum
Steps:
Note: the software filters the input features according to the datum creation rules above and adopts only the features that meet the rules; other features do not participate in the creation.

Caption: Figure 6-3-1 Create a fitted cylinder on the scan model

Caption: Figure 6-3-2 Select a fitted cylinder that meets the datum rules as an axis datum

Caption: Figure 6-3-3 Use the axis datum to measure the geometric tolerance (total runout) of the fitted cylinder
6.3.2 Coordinate System
A coordinate system is a reference coordinate system with a specified axis orientation and origin. It supports the coordinate transformation and evaluation of geometric features, as well as coordinate system alignment of models.
6.3.2.1 Coordinate System Composition
A coordinate system is constructed from point, line, and plane features according to rules. Two construction methods are available: plane-line-point and line-line-point. The input features must be constructed in advance.
| Construction Method | Input Features | Axis Rule | Applicability |
|---|---|---|---|
| Plane-line-point | 1 plane, 1 line, 1 point | Taking Z-Y-X as an example: the plane defines the Z direction, the cross product of the plane and the line defines the Y direction, and the X axis passes through the point | Preferred when a reliable plane exists |
| Line-line-point | 2 lines, 1 point | Taking Z-Y as an example: the first line defines the Z direction, the cross product of the first and second lines defines the Y direction, and the origin is located at the point | Used when no reliable plane exists |
6.3.2.2 Rules
6.3.2.3 Creating a Coordinate System
Plane-Line-Point
Steps:

Caption: Figure 6-3-4 Construct the point, line, and plane features required for the coordinate system

Caption: Figure 6-3-5 Select the constructed point, line, and plane features

Caption: Figure 6-3-6 Plane-line-point coordinate system created
Line-Line-Point
Steps:

Caption: Figure 6-3-7 Construct the two lines and one point required for the coordinate system

Caption: Figure 6-3-8 Select the constructed two lines and one point

Caption: Figure 6-3-9 Line-line-point coordinate system created
Basic Measurement includes Angle Measurement, Measure Length, and Measure Radial Distance. For information on selecting measurement targets, see 6.1 "Selecting Measurement Targets".
6.4.1 Angle Measurement
Measures the angle formed by point, line, and plane features
Click the Angle Measurement drop-down and select one of the following methods according to the measurement object:
| Measurement Method | Measurement Object | Required Features |
|---|---|---|
| Three-Point Angle | The angle formed by a vertex and two end points | 3 points |
| Angle Between Two Lines | The angle between two lines or axes | 2 lines |
| Angle Between Two Planes | The angle between two planes | 2 planes |
| Angle Between a Line and a Plane | The angle between a line and a plane | 1 line + 1 plane |
Operation steps:
Notes for each method:
Tip: measurement targets can be existing features, or point features created quickly with Shift during selection; see "Selecting Measurement Targets".

Caption: Figure 6-4-1 Three-Point Angle

Caption: Figure 6-4-2 Angle Between Two Lines

Caption: Figure 6-4-3 Angle Between Two Planes

Caption: Figure 6-4-4 Angle Between a Line and a Plane
Measures the distance between point, line, and plane features
Click the Measure Length drop-down and select one of the following methods according to the measurement object:
Measurement Method Measurement Object Required Features
Distance Between Two Points The distance between two points 2 points
Distance from Point to Straight Line The perpendicular distance from a point to a line 1 point + 1 line
Distance from Point to Plane The distance from a point to a plane 1 point + 1 plane
Distance Between Two Straight Lines The distance between two lines 2 lines
Distance from Straight Line to Plane The distance from a line to a plane 1 line + 1 plane
Distance Between Planes The distance between two planes 2 planes
Maximum Distance Between Planes The maximum distance between two planes 2 planes
Operation steps:
Notes for each method:
Tip: measurement targets can be existing features, or point features created quickly with Shift during selection; see "Selecting Measurement Targets".

Caption: Figure 6-4-5 Distance Between Two Points

Caption: Figure 6-4-6 Distance from Point to Straight Line

Caption: Figure 6-4-7 Distance from Point to Plane

Caption: Figure 6-4-8 Distance Between Two Straight Lines

Caption: Figure 6-4-9 Distance from Straight Line to Plane

Caption: Figure 6-4-10 Distance Between Planes

Caption: Figure 6-4-11 Maximum Distance Between Planes
6.4.3 Measure Radial Distance
Measures the radius or diameter of circle, sphere, and cylinder features
Click the Measure Radial Distance drop-down and select one of the following methods according to the measured feature:
| Measurement Method | Measured Feature | Measurement Content |
|---|---|---|
| Circle Radial Measurement | Circle | Radius / diameter |
| Sphere Radial Measurement | Sphere | Radius / diameter |
| Cylindrical Radial Measurement | Cylinder | Radius / diameter |
Notes for each method:
Tip: measurement targets can be existing features, or point features created quickly with Shift during selection; see "Selecting Measurement Targets".

Caption: Figure 6-4-12 Circle Radial Measurement

Caption: Figure 6-4-13 Sphere Radial Measurement

Caption: Figure 6-4-14 Cylindrical Radial Measurement
Uses existing geometric features to evaluate form, orientation, location, or runout deviations
Geometric tolerances include:
| Category | Tolerance |
|---|---|
| Form tolerance | Flatness, cylindricity, circularity, straightness |
| Orientation tolerance | Parallelism, perpendicularity, angularity |
| Location tolerance | Coaxiality, position, symmetry |
| Runout tolerance | Circular runout, total runout |
| Profile tolerance | Profile of a surface |
6.5.1 General Workflow
All tolerance dialogs share the same structure and are divided into the following areas:
| Area | Description |
|---|---|
| Name | Tolerance name; automatically numbered as "tolerance name + serial number" by default and editable |
| Geometric Parameters | Select the measured feature, scan model, datum (displayed only for tolerances that require a datum), and direction (optional) |
| Auxiliary Parameters | Tolerance value, i.e., the tolerance zone width |
| Text Parameters | Theoretical values such as design perspective, design size, and design radius; entity requirements; and the upper and lower limits of the dimensional tolerance. Provided only for some tolerances and used for annotations in the inspection report |
| Professional Parameters | Advanced options, collapsed by default |
Operation steps:
| Tolerance | Typical Measured Feature | Datum | Specific Parameters |
|---|---|---|---|
| Flatness | Plane | Not required | — |
| Straightness | Line or axis | Not required | Calculation type: axis straightness / plain line straightness |
| Circularity | Circle or cylinder cross-section | Not required | — |
| Cylindricity | Cylinder | Not required | — |
| Profile of a Surface | Surface | Not required | — |
| Parallelism | Plane, line, or axis | Required | — |
| Perpendicularity | Plane, line, or axis | Required | — |
| Angularity | Plane, line, or axis | Required | Design perspective |
| Position | Point, circle, slot, or axis | Required | Design size |
| Coaxiality | Axis | Required | — |
| Symmetry | Center plane or center line | Required | — |
| Circular Runout | Surface of revolution | Required | — |
| Total Runout | Surface of revolution | Required | — |
Apart from the differences listed above, the dialog fields and operation steps of each tolerance are identical to the general workflow.
6.5.3 Key Points
6.5.4 Flatness
Checks the flatness of a planar surface
6.5.5 Cylindricity
Checks the form deviation of the entire cylindrical surface
6.5.6 Circularity
Checks whether the circular profile is close to a true circle
6.5.7 Straightness
Checks the bending deviation of a line or axis
6.5.8 Parallelism
Checks whether the measured feature remains parallel to the reference datum
6.5.9 Perpendicularity
Checks whether the measured feature remains perpendicular to the reference datum
6.5.10 Angularity
Checks the orientation deviation between the measured feature and the reference datum
6.5.11 Coaxiality
Checks whether the measured axis and the reference axis remain on the same center axis
6.5.12 Position
Checks the deviation of the measured feature from its theoretical position
6.5.13 Symmetry
Checks whether the measured feature remains symmetric about the reference center plane or center line
6.5.14 Circular Runout
Checks the runout deviation of a single cross-section of a surface of revolution relative to the datum axis
6.5.15 Total Runout
Checks the overall runout deviation of a surface of revolution relative to the datum axis
6.5.16 Profile of a Surface
Checks the deviation between the actual surface and the reference shape
Projects features from the reference model onto the scan model to establish the correspondence between reference features and scan features
Projection solves the following problem: a one-to-one association must be established between a reference feature (a point, line, or plane on the CAD model) and the actual surface of the scan model so that RPS Alignment, Dimensional Deviation, and other functions can reference the feature pair. The software provides two projection methods:
| Projection Method | Source of the Scan Feature | Applicability |
|---|---|---|
| Associated Projection | The user has already created the feature on the scan model and specifies the correspondence during projection | Fitted features are already available on the scan model, or the correspondence must be controlled precisely |
| Best-Fit Projection | The software automatically fits and generates the feature on the scan data from the reference feature | Only the reference model needs features; manual operations should be minimized for efficiency |
Common prerequisites for both methods:
6.6.1 Associated Projection
Associates a reference feature with an existing corresponding feature on the scan model
Dialog parameters:
| Parameter | Description |
|---|---|
| Name | Projection name; automatically numbered as "Associated Projection + serial number" by default and editable |
| Reference Geometry | Select the reference feature on the reference model |
| Scan Geometry | Select the corresponding feature already created on the scan model |
Operation steps:
Key points:

Caption: Figure 6-6-1 Construct a plane feature on the reference model

Caption: Figure 6-6-2 Construct a plane feature on the scan model

Caption: Figure 6-6-3 Select the two features to be associated

Caption: Figure 6-6-4 Result after associated projection
6.6.2 Best-Fit Projection
Projects the reference feature onto the scan model and automatically fits the corresponding scan feature
Dialog parameters:
| Parameter | Description |
|---|---|
| Name | Projection name; automatically numbered as "Best-Fit Projection + serial number" by default and editable |
| Reference Geometry | Select the reference feature on the reference model |
| Scan Model | Select the scan model |
| Use fixed distance | When selected, the fitting search range is limited to a fixed distance, and the distance value is entered on the right; when cleared, the software determines the search range automatically |
| Maximum Normal Vector Angle | The maximum deviation angle allowed between the normal of the scan surface participating in the fit and the normal of the reference feature; the default is 20° |
Operation steps:
Key points:

Caption: Figure 6-6-5 Create a feature on the reference model

Caption: Figure 6-6-6 Select the feature for Best-Fit Projection

Caption: Figure 6-6-7 Result after best-fit projection
6.6.3 Managing and Using Projection Results
After projection, an association is formed between the reference feature and the scan feature. It can be used for:
Maintaining the projection relation:
6.7 Template Inspection
Saves a completed inspection workflow as a template and automatically runs the same inspection on parts of the same type
Template Inspection is intended for repeatedly running the same inspection workflow on parts of the same type. After the first inspection is complete, save the model alignment, geometric features, projections, measurements, and geometric tolerances as a template; when inspecting a new part of the same type, run Template Inspection to reproduce the entire workflow automatically without repeating each step.
Template Inspection includes two functions:
| Function | Purpose | When to Use |
|---|---|---|
| Save as Template | Saves the inspection content of the current project as a template file | After the first inspection is complete and all inspection content is confirmed |
| Template Inspection | Creates a new project and runs the inspection automatically with the template | When inspecting a new part of the same type |
6.7.1 Save as Template
Saves the completed inspection content of the current project as a reusable template file
Dialog parameters:
| Parameter | Description |
|---|---|
| Path | Save path of the template file; defaults to the temporary folder in the software installation directory and can be changed by clicking the folder icon on the right |
| Name | Template name; must be entered manually |
Operation steps:
Key points:

Caption: Figure 6-7-1 Save inspection template
6.7.2 Template Inspection
Creates a new inspection project, selects the inspection template and the detected model, and automatically runs the inspection workflow in the template
After you click Template Inspection, the software prompts you to save the current project first, then creates a new project and enters the template inspection workflow.
Dialog parameters:
| Parameter | Description |
|---|---|
| Inspection Template | Select the saved template file |
| Detected Model | Select the scan model for this inspection |
Operation steps:
Key points:

Caption: Figure 6-7-2 Import the inspection template and model

Caption: Figure 6-7-3 Run template inspection

Caption: Figure 6-7-4 Template inspection completed
6.7.3 Applicability of Template Inspection
Scenarios suitable for templates:
Scenarios not suitable for templates:
Organizes inspection results, fills in report information, previews, and exports the inspection report
Report output includes two functions: Create Report Page organizes inspection results into image-and-table pages, and Generate Report consolidates the content and exports it.
| Function | Purpose |
|---|---|
| Create Report Page | Selects inspection results and generates report pages containing images and tables; multiple pages can be created |
| Generate Report | Fills in report information, selects report content, previews, and exports |
Operation steps:
The report page is listed under Inspection Report in the project tree and can be deleted and recreated.

Caption: Figure 7-1 Create Report Page
Operation steps:
The report content usually includes the reference model, scan model, model alignment result, deviation analysis, and created report pages.
The report is exported as a PDF file; select the save location and enter a file name when exporting.

Caption: Figure 7-2 Generate Report
View the name, type, and geometric parameters of the currently selected object.
Operation steps:
View the measured value, tolerance, and judgment result of the currently selected inspection item.
Operation steps:
Different inspection types can display different fields, for example:
The inspection results area shows only the currently selected inspection item and does not merge results with different fields.

Caption: Figure 8-1 View object properties and inspection results
Which purpose should I select when importing a mesh model?
Select Reference Model if the model represents the design standard or inspection datum; select Scan Model if the model comes from actual scan results.
What should I do if automatic alignment is incorrect?
Use Manual Alignment to select three corresponding points and establish the initial position, then run Automatic Alignment again. If only a local region is of interest, use Local Alignment.
Why can't I select objects in Datum Alignment?
Datum Alignment requires the corresponding geometric features and datums to be created in advance. Check whether usable features exist on both models.
Why can't Coordinate System Alignment be executed?
Confirm that coordinate systems have been created on both the reference model and the scan model, and check the origin and axis directions.
Why can't I select the required object when creating a feature?
The current feature may depend on other geometric features. Create the dependent features first, then perform the current operation.
Why can't the geometric tolerance be calculated?
Check the following:
Why are not all inspection results displayed?
Different inspection types use different fields, so the results area shows only the currently selected inspection item. All inspection content can be organized and output through the inspection report.
How do I restore a hidden object?
Click the closed-eye icon next to the object, or select Show All.
How do I inspect parts of the same type repeatedly?
Save the completed inspection content as a template first. Next time, click Template Inspection, save the current project as prompted, select the inspection template and the detected model in the new project, and click Start.
Can I export a report without uploading a logo?
Yes. The logo is optional and does not affect report preview or export.