Ender 3V3 KE screen blinks after the vibration sensor is connected
The connecting wire of the vibration sensor kit has poor incoming materials, and there is a short circuit problem inside the Type-C port position.
Reissue the vibration sensor Type-C connection wire (Part number: 3103110575) in the Nebula screen kit
Note:
The vibration sensor Type-C wire in the Nebula screen kit has a USB port, which is used to connect the Nebula camera or other 5V device power supply, do not plug the Nebula screen USB port.